100 Series : Thermocouple & Resistance Thermometer inserts / probes
 
 
Thermocouple and Resistance Thermometer inserts / probes
Thermocouple and Resistance Thermometer inserts/probes

• Manufactured as per IEC 1515 - 1995
• Metal Sheathing and mineral insulation    reduces overall size of inserts.
• Can be used at relatively higher temperatures.
• Pliable and can be routed through high temperature environment.
• Available with a choice of cold end termination(CJTs) and connectors.
• Available in ANSI TC Types J, K, T, E, N, R, S & B ( IEC - 584 - Part 1, 2 & 3)
• Certified for use in hazardous area.
 
 
 
Thermocouple and Resistance Thermometer inserts / probes
 
 
Thermocouple and Resistance Thermometer inserts / probes
• Available in ANSI TC Types J, K, T, E, N,   R, S & B (IEC - 584 - Part 1, 2 & 3)
• Pt100 RTDs to IEC 751-1995
• Ungrounded hot junction as a   standard feature.
• Integral Lead wires with PTFE or   Fibreglass insulation.
• Special designs to suit your applications.
 
 
 
MS MI TC CABLE DETAILS (Base Metal TCs)
Thermocouple and Resistance Thermometer inserts / probes
Ms Mi Thermocouple sensors employ a metal sheathed, Mineral insulated cable with matched Thermo-couple conductors. The insulation is a compacted mass ofMgO and this heterogenous cable, when Converted into a Thermocouple sensor offers many unique advantages over the conventional ceramic bead insulated Thermocouples. Ms Mi Thermocouple sensors are pliable, can be bent, coiled, routed through bends or intricate paths, bundled together to form a Multiple sensor assembly or welded to a tube or any any surface to measure skin temperatures. The junction and Thermocouple conductors are not exposed to process fluids thus ensuring a longer usable life.

Ms Mi Thermocouples sensors are generally supplied with their hot junction isolated or ungrounded from the sheath. This enables the users to carry out periodical checking of the Thermocouple sensors. Bonded or grounded junction sensors are also supplied against request.

Ms Mi Resistance Thermometer sensor incorporates a wire wound element conforming to IEC 751-1995 class "A" or "B". The element leads are extended to the open end of the sensor by means of a Ms Mi Transducer lead out cable employing copper conductors, compact mass ofMgO as insulation and stainless steel sheath conforming to AISI 316. The standard overall sheath diameter available are 6 mm and 3.2 mm employing Ms Mi cable of 5 mm and 2.8 mm dia respectively.

Sensors, when built up, are subject to all the routine tests as per mc 751-1995. Type tests and any other special test can be carried out by mutual aggrement
 
 
Ordering Example
100 Series 1-K-6-316-CJT101-RL-A-1-C-Option 21
 
 
 121 Series : Thermocouple & Resistance Thermometer Assemblies, Less Well
 
 
Thermocouple & Resistance Thermometer Assemblies, Less Well • Suitable as replacement for existing    installations.
• Various head assembly types to choose    from
• Flame proof or weather proof execution.
• Terminal Head in die cast Aluminum or in    SS316.
• Available with "in head", 2 wire   temperature Transmitter.
 
 
 
Thermocouple & Resistance Thermometer Assemblies, Less Well
 
 
Ordering Example
110 Series 1-Pt-6-316-D-1-HA105-E-N=75-3-Option 0
 
 
 120 Series : Thermocouple & Resistance Thermometer Assemblies, Less Well
 
 
Thermocouple & Resistance Thermometer Assemblies, Less Well

• With choice of adjustable connectors.
• Long, pliable MI lead out, where required    for    intricate installation and high    temperature route.
• Weather proof or flame proof execution    in 316SS    or Aluminum.
• Available with "in head" 2-wire    temperature   Transmitter.

Ms Mi Thermocouple or Resistance Thermometers can be provided with a long MI lead out cable to enable its usage in intricate installations and in high temperature environment.

Typical application are turbine casing, SH/RH and drum metal temperature measurements in Power Plants and measurement of temperature in high temperature application in Fertilizer and Petrochemical Plants.

These Thermocouples can be provided with suitable connectors, weld pads and other accessories for particular use.

Thermocouples are provided with ungrounded junction unless specified otherwise.

 
 
 
Thermocouple & Resistance Thermometer Assemblies, Less Well
 
Ordering Example
120 Series 2-K-6-316-D-2-B-1/2"B-1/2"N-OL=15M-Options 13 &14
 
 121 Series : Thermocouple & Resistance Thermometer Assemblies with
 
Thermocouple & Resistance Thermometer Assemblies

• Integral Collar
• Long, pliable MI lead out, ideal for skin    temperature measurement.
• Weather proof execution in SS or    Aluminum.
• Available with "in head", 2 wire    temperature   Transmitter.
• Bracket mounting or 2"Nb pipe    mounting.

MsMi Thermocouple or Resistance Thermometers can be provided with a long MI lead out cable to enable its usage in intricate installations and in high temperature environment. An integral collar enables the Thermocouple to be fitted on the vessel/reactor surface.

Typical application are measurements of surface temperature of refractory lined vessels, columns, reactors in petrochemical plants and oil refineries.

These Thermocouples can be provided with a bracket for surface mounting or for mounting on 2" Nb pipe.

Thermocouples are provided with ungrounded junction unless specified otherwise.

 
Thermocouple & Resistance Thermometer Assemblies
 
Ordering Example
121 Series 2-K-6-316-D-2-B-1/2"B-1/2"N-OL=15M-Options 13 &14
 
 122 Series : Thermocouple & Resistance Thermometer Assemblies with
 
Thermocouple & Resistance Thermometer Assemblies • Weld pad or "Strap on" pad
• Long, pliable MI lead out, Ideal for skin    temperature   measurement for pipe or    vessel surface.
• Weather proof execution in SS or    Aluminum.
• Available with "in head" 2-wire   Temperature    Transmitter.
• Bracket mounting or 2"Nb pipe   mounting.

MsMi Thermocouple or Resistance Thermometers can be provided with a long MI lead out cable to enable its usage in intricate installations and in high temperature environment. A seperate weld pad or " Strap-on" pad is provided for fixing the Thermocouple to vessel/ reactor or on pipe surface.

Typical application are measurements of surface temperature of refractory lined vessels, columns, reactors in petrochemical plants and oil refineries and pipelines.

These Thermocouples or RTD's are provided with a bracket for surface mounting or for mounting on 2" Nb pipe.

Thermocouples are provided with ungrounded junction unless specified otherwise.
 
Thermocouple & Resistance Thermometer Assemblies
 
Ordering Example
122 Series 2-Pt-6-316-D-2-B-1/2"N-C-OL=3M-Options 28
 
 123 Series : Thermocouple & Resistance Thermometer Assemblies with
 
Thermocouple & Resistance Thermometer Assemblies

• "Strap on" for pipe surface temperature
   measurement.
• Pliable MI lead out. Ideal for Skin   Temperature measurement of pipe   surface.
• Weather proof execution in SS or   Aluminium.
• Available with "in head" 2.wirc
  Temperature Transmitter.
• Quick disconnect jack for using with
  band held monitor.

 

Ms Mi Thermocouple or Resistance Thermometers can be provided with a Pliable MI lead out cable to enable its usage in intricate installations ~ for strapping on the pipe surface for skin temperature measurement of gas / oil pipe tines or heat-traced pipe lines.

These Thermocouples or RIDs are provided with a stand out nipple for local mounting.

Thermocouples are provided with ungrounded junction unless specified other Wise
 
Thermocouple & Resistance Thermometer Assemblies
 
Ordering Example
123 Series 1-Pt-6-316-D-1-L-N=200-D=32"-EL=200-Options 28 & 40
 
 124 Series : Thermocouple & Resistance Thermometer Assemblies with
 
Thermocouple & Resistance Thermometer Assemblies

• Weld pad
• Long, pliable MI lead out. Ideal for Skin Temperature measurement for vessel   surface.
• Weather proof or flame proof execution   in SS or Aluminum
• Available with "in head" 2-wire Temperature • 2- wire Temperature Transmitter. Bracket mounting or 2"Nb pipe mounting.

               
 
Thermocouple & Resistance Thermometer Assemblies
 
Ordering Example
124 Series 2-E-6-316-D-2-B-1/4"N-E-E(Inc 600)-OL=6M-Options 15
 
 
 
Home | About Us | Company Profile | Our Associate Companies | Our Setup | Our Partner & Joint Venture | Products | Temperature Sensors | Thermocouples & RTD Assemblies | 100# Thermocouples / RTD Inserts without Thermowells | 300# Thermocouples / RTD Assemblies with Threaded Thermowells | 400# Thermocouples / RTD Assemblies with Flanged Thermowells | 500# Thermocouples / RTD Assemblies with Weld in Thermowells | 600# Thermocouples / RTD Assemblies with Protecting Tubes | Thermowells | 300# Threaded Thermowells | 400# Flanged Thermowells | 500# Weld in Thermowells | Special Assemblies | 800# Wedge Shaped Skin Thermocouples | Catalyst Profiler Multipoint Thermocouple | Dual Type Sensors | Temperature Gauges | TG 100# Bimetal Temperature Gauges | TG 110# Ragid System Mercury in steel or Insert Gas Filled Temperature Gauges | TG 120# Capillary Type Mercury in Steel or Insert Gas Temperature Gauges | Tables | Pressure Gauges | PG 100# Bourdon Sensing Pressure Gauges | PG 101# Capsule Sensing Pressure Gauges |  PG 110# Pressure Gauges with Chemical Seal Unit & Threaded Process Connection | PG 120# Pressure Gauges with Chemical Seal Unit & Flanged Process Connection | PG 130# Pressure Gauges with Chemical Seal Unit & Flanged Process Connection | PG 140# Diaphragm Sensing Pressure Gauges with Threaded Process Connection | PG 150# Diaphragm Sensing Pressure Gauges with Flanged Process Connection |  Tables | Special Assemblies | Flow Elements | Orifice Plates and Assemblies | FE 100# Orifice Plates | FE 400# Orifice Assembly with Flange Taps | FE 410# Orifice Assembly with Corner Taps | FE 410 CR# Orifice Plate with Carrier Ring Assembly | FE 410 IMR# Integral Orifice Meter Run Assembly | FE 440 OS # Orifice Assembly with D-D/2 Taps | Restriction Orifice Plates & Assemblies | FN 400# Long Redius Flow Nozzles | Tables | Flow Nozzles | Venture | Crenditials | Installation | Contact Us | Feedback | Sitemap
 